1334–1348 Stockton Street
Hotel
-
1907
Built.
-
January 25, 1907
Frank J. Klinn contracted for plumbing, drainage and gas fitting on a three-storey and basement building.
-
October 1971
It traded as the Villa Rosa, an 85-unit residential hotel; one unit stood vacant.
-
Nov 1990
Reroofing.
-
Jul 2005
Instlll 1 duct to monitor existing local facu monitoring. required due to the recent retrofit of the fire.
-
Mar 2011
Wallgreens. addition of new refrigeration, new mill work at check out and employee room, new flooring at pharmacy, sales, entry, meeting room, and employee room. new countertops, wall finishes, decor package, new ceiling and lighting. relocate office and mtg room. expand pharmacy.
-
Nov 2012
New fa system for the hotel. 2nd & 3rd floors-replace panel & existing system because of chronic problems, commercial on 1st floor apartments on 2nd & 3rd fl. fire alarm control panel.
-
Jul 2013
Replace 5/8" sheetrock on 2/f one unit and hallway ceiling (640 sq) type "x".
-
Jun 2018
To renew & obtain final inspection for work approved under permit application 200206270135. all work is complete.
-
Dec 2018
To obtain final inspection for work approved under permit application 201211214693. all work is complete.
-
Oct 2019
Reroofing.
-
Oct 2019
1. replace all windows (approx 75) at rear building. exclude front side building. 2. repair water damage exterior wall at rear. 3. install new 1" x 8" hardy siding around rear side of building including central light view. 4. exterior painting of the entire building except front side.
-
Nov 2019
To comply with nov #201803411. soft story retrofit per sfebc chapter 4d engineering criteria asce 41-13. install new brace frame at the gorund fl, at front side of the building. to comply with ordinance 66-13 for tier iv building.
-
Feb 2022
Install new concentric brace frame at the ground fl, at the store front to comply with ordinance 66-13. to comply with nov# 201803411. soft story rertofit per sfebc chapter 4d engineering criteria asce 41-6. (residential) ref permit application 202202178252 for commercial soft story.
-
Feb 2022
Install new concentric brace frame at the ground fl, at the store front to comply with ordinance 66-13. to comply with nov# 201803411. soft story rertofit per sfebc chapter 4d engineering criteria asce 41-6. (commercial) ref permit application 202202178247 for residential soft story.
-
Jan 2023
Removal and replacement of condensing unit and air handling units of a rtu on a commercial building.
4 nominal $1 street-space or sidewalk permits are omitted from the timeline. 9 expired or cancelled permits are not shown.