476–480 Eddy Street
35-unit apartment building
-
1924
Built as the Bonita Apartments, apartment building with 35 2-room units, to the design of the architect Edward E. Young. Six storeys over a basement, steel frame structure with brick and tile walls, two-part vertical composition, Renaissance/Baroque ornamentation.
-
Jun 1983
Repair of parapet and chimney.
-
Nov 1983
Comply with rap report & specifications.
-
Jun 1984
Install new water main service remove water storage tank.
-
Feb 1990
Demolition of damaged plaster ceiling & install 5/8" gpboard.
-
Nov 1990
Patch & retouch paint.
-
Nov 1990
Install new coancrete wall, poxy grove brick walls.
-
Mar 1993
Exist off spac converted to donut/coffee shop/non-struc wall.
-
Nov 1994
Reroofing.
-
Nov 2013
Upgrade new fire alarm contrl panel.replace conven'l appl to addressable.add horns in each unit.add(2)new pull statn 1/fl.replace all corridor smke detrs.add1 smke detr on 1/fl lobby.add(2)new smke detrs 1/fl com spc.add 2 heat detrs at 1/fl restrm com spc.replcexistingbells in corrw/newhorns/strobes.
-
Mar 2017
Remodel exgt vacant office space. add partition walls upgrade handicap toilet and new mechanical. n/a for maher.
-
Aug 2017
T.i. on the 1st floor by relocating and adding a few fire alarm devices. ref app#201703312939. n/a for maher.
-
Aug 2017
Revision to 201703312939. replace heat pump for electrical heat maher not req.
-
Apr 2019
Review for final inspection only. 201311211592.
-
Dec 2019
100% affordable & priority process housing. the scope of work includes the renovation of 32 units of 100% affordable housing in a six story building, a voluntary seismic upgrade, mechanical, electrical & plumb upgrades, and ground floor alterations for accessibility improvement will also be included.
-
Nov 2022
Underground fire service tie-in with in-building riser.
-
Dec 2022
Install new 6" ductile iron fire line approx 6' from tie-in @ curb to 6" in-building riser. 6" ames colt c300 backflow preventer with tamper switch install in commercial space off stub-in.
-
Mar 2023
Revision to permit application 201912190012-s1, new voluntary steel moment frame at ground floor to mitigate existing soft-story and open front condition. sprinklers/fire alarm under separate permits.
-
Aug 2023
Revision to bpa#201912190012, add attic protection above level 6, fire walls to be added by gc.
-
Aug 2023
Add 1-hour rated walls in attic from the ceiling to under side of roof deck @ locations shown in bpa#201912190012s1.
-
Sep 2023
Revision to permit 201912190012/s1. adding multiple masonry anchors to the existing parapet masonry, securing the anchors to cold formed steel framing that is connected to the structural building frame.
-
Mar 2024
Install evacuatin maps for floors 1 to 6.
-
Sep 2024
Tenant improvement of the ground floor commercial space of the historic yosemite apartment.
4 nominal $1 street-space or sidewalk permits are omitted from the timeline. 2 expired permits are not shown.
Nearby
- 469 Eddy Street Same street
- 481–485 Eddy Street Same street
- 484–490 Eddy Street Same block
- 300–302 Hyde Street Same block
- 466 Eddy Street Same block
- 324 Hyde Street Same block
- 305 Hyde Street Around the corner
- 240 Hyde Street Around the corner