936–940 Geary Street
32-unit apartment building
-
1920s
A grocery run by a Russian émigré — later the president of the Russian Center — traded here in the 1920s and 1930s.
-
1922
Built as the Geary Apartments, apartment building with 32 2-room units, to the design of the architect Woodworm Wethered. Six storeys over a basement, reinforced concrete structure, two-part vertical composition, Renaissance/Baroque ornamentation.
-
1923
Built.
-
Jun 1989
New roof and parapet.
-
Jun 2019
Remodel commercial storefront entrance to comply with mandatory disability access improvement program.
-
Mar 2022
Over the counter window replacement in kind (like-for-like). 136 windows total. 66 new vinyl windows. 70 aluminum clad wood windows street facing. all windows same size, same location, max u-factor=0.58, max rshgc=0.41, min vt=0.42 fixed/0.32 operable.
-
Jun 2022
Voluntary ground floor lateral retrofit of existing type 3 structure with steel ordinary moment frame & new concrete foundation at front & rear of structure. accessible upgrades to existing commercial bathroom.
-
Aug 2022
Interior residential remodel- working in 31 units total like for like replace: bath remodel (sink, toilet, vanity). replace unit entry and closet doors, refurbish hard wood floors, replace cabinets in kitchen in select units, interior paint and wall patching. re-glaze bath tubs. f/a on sep permit.
-
Aug 2022
Reinstate sewer line from floor level clean out to curb with 20 miller. remove all existing hydronic system, cut/ cap pipe to be hidden in floor. find and repair leaks add shut off valves as needed to each unit. replace coin operated washer & dryer in laundry room to match existing. dryer cmc 908 with shutoff.
-
Sep 2022
Structural revision to bpa# 202206287283 (voluntary retrofit) relocate rear steel moment frame 10'-0" behind garage door opening. modify lateral bracing. add plywood to ceiling for cantilever diaphragm.
-
Apr 2023
Reroofing.
-
Jul 2023
Upgradae existing fire alarm system to comply with sffc section 1103.7.6.1.
-
Sep 2023
Adding class ii standpipe to the existing geary st. class i standpipe including signage for a demand of 500 gpm @ 132 psi.
1 nominal $1 street-space or sidewalk permit is omitted from the timeline. 2 expired permits are not shown.
Nearby
- 931–935 Geary Street Same street
- 937–941 Geary Street Same street
- 946 Geary Street Same block
- 928–930 Geary Street Same block
- 950 Geary Street Same block
- 920 Geary Street Same block
- 920 Larkin Street Around the corner
- 926–932 Larkin Street Around the corner