  1. Aug 1990
    Permit 9015292 $$$ $20,500

    Install new toilets, sinks, ect.

  2. Oct 1990
    Permit 9022280 $$$ $50,000

    Remodel existing offices, remove relocate partition walls.

  3. Nov 1998
    Permit 9823576S $$$ $1,900,000

    Erect a one story wholesale sales building.

  4. Jan 2000
    Permit 20000105262 $$$ $112,000

    Install 795 sprinkler heads for fire protection.

  5. Mar 2000
    Permit 200003063530 $$$ $95,000

    Tenant improvement-install additional sprinkler for rack & freezer areas.

  6. May 2000
    Permit 200005240806 $$$ $45,000

    Installation of rack system.

  7. May 2000
    Permit 200005311399 $$$ $100,000

    1 hour property line wall const. detail for app #9823576s.

  8. Jul 2000
    Permit 200007205668 $$$ $7,000

    Install walkin box cooler an freezer box.

  9. Aug 2000
    Permit 200008036842 $$$ $20,000

    Frame and close walls all other permits to be applied for separateley ref only#9823576s ck access on.

  10. Aug 2000
    Permit 200008299135 $$$ $40,000

    Fire alarm sprinkler monitoring system installation fire alarm system.

  11. Oct 2000
    Permit 200010042306 $$$ $15,000

    Erect a double-faced projecting-freestanding electrical sign.

  12. 2002

    Built.

  13. Jun 2003
    Permit 200306237699 $$$ $10,000

    Reface 2 existing signs.

  14. Jun 2012
    Issued Permit 201206051876 $$$ $13,282

    Provide fire sprinklers (51) to new metal exterior canopy. ref permit application 2010.1119.5309.

  15. Nov 2012
    Permit 201211214716 $$$ $329,600

    Installation of a new esfr fire sprinkler system within new warehouse, upgrade and relocate existing piping, additional sprinkler bracing where required. system to be connected to existing fire pump. 683 new sprinkler heads.

  16. Dec 2012
    Permit 201212126055 $$$ $25,000

    Reroute ug fire lines for sprinkler addition to existing building. installing new 6" ductile iron ug to existing fdc's and system supply installing new 8" underground from evans stree to existing fire pump. reference sprinkler system app.# 2012-1121-4716 ti permit application 2010-11-19-5309.

  17. Dec 2012
    Issued Permit 201212286958 $$$ $7,000

    Phase 1-relocate sswf fire panel to temporary locations. monitoring sprinklers & fire pump & sd. as of nfpa 72 2010, relocate horn strobe, pull station, smoke detector to new location in offices due to build out of building structure. ti permit application 2010-1119-5309.

  18. Feb 2013
    Permit 201302220776 $$$ $26,000

    Phase ii t.i. upgrade of dedicated auto sprinkler system fire panel to addresseable system. adding full occupant notification, pull stations at all exits & air handler duct detector monitoring. ref permit application 2010.1119.5309. 16 pull station, monitor water flow and sprinklers on sep permit.

  19. Mar 2013
    Permit 201303212681 $$$ $15,000

    Install 3 non illunimated wall signs.

  20. Apr 2013
    Permit 201304195021 $$$ $20,890

    Installation of new in-rack fire protection system, 19 new heads. reference app. # 2012-1121-4716.

DBI holds 41 permits for this parcel, most of them tenant improvements on individual floors. The timeline shows the 24 largest by stated cost, plus the earliest on file; the DBI query in the sources below returns all 41. 5 expired permits are not shown.