Know This Place

District 3 · Block 0306, Lot 012 · ZIP 94102

Marland Hotel

490–498 Geary Street

  • Hotel
  • 7 stories
  • 27,600 ft2
  • 3,450 ft2 lot area
  • 67 residential units
  • 73 rooms
  • 68 bathrooms
  • Zoned C3G
  • Historic resource
  • Sold December 31, 1991
37.7871, −122.4113 Street View appears here once a Google Maps embed key is configured.
  1. 1912

    Built.

  2. Mar 1984
    Permit 8402971 $$$ $1,200

    Sign - erect.

  3. Apr 1985
    Permit 8503247 $$$ $10,000

    Demolition of interior partitions (nonbearing plans.

  4. Sep 1985
    Permit 8509939 $$$ $10,000

    Structural alterations in the basement.

  5. Dec 1985
    Permit 8513671 $$$ $6,000

    Complete automatic sprks. system.

  6. Apr 1986
    Permit 8604105 $$$ $12,000

    Install new dry stand pipe.

  7. Oct 1986
    Permit 8613219 $$$ $150,000

    Install new interior partitions, ceiling, plumbing.

  8. Dec 1987
    Permit 8717105 $$$ $12,500

    Drywall, drop ceiling.

  9. Apr 2013
    Permit 201304114284 $$$ $40,000

    Redecorate 1 guest room & 1 suite and remodel 1 guest bathroom @ 6th floor; upgrade entry, path of travel & elevators for accessibility, install new platform lift @ 1st floor; mechanical, electrical & fire sprinkler under separate permit.

  10. Apr 2013
    Issued Permit 201304114298 $$$ $20,000

    Ground floor facade modificiations. awnings, replacing pair of doors with fixed glass, light fixtures, new text on marques. path of travel upgrades. mechanical, electrical, fire sprinkler under separate permit. ** maher: compliance with ordinance no# 155-03 not required **.

  11. Jun 2013
    Permit 201306139447 $$$ $350,000

    Install energy efficent split heatpumps to replace existing electric radiant ceiling panels in guest rooms and heating fancoil units in basement and 1st floors. no lighting changes.

  12. Aug 2013
    Issued Permit 201308265189 $$$ $1,100,000

    Ground floor interior remodel, upgrade entry, path of travel, elevators and restrooms for accessibility, mechancial & fire sprinkler work under seperate permit.

  13. Dec 2013
    Permit 201312315347 $$$ $600,000

    Revision to 201308265189- construction phase addition to 201304114284 (under review) to increase remodel to 74 rooms total. 4 are fully accessible, 2 have roll in showers. gr fl work under 201308265189. mechanical, electrical, sprinkler under sep permit.

  14. Jan 2014
    Issued Permit 201401247033 $$$ $10,000

    Upgrade existing conventional fire alarm system to a new addressable fire alarm system to accomodate new devices. all existing field devices shall remain and be monitored by modules connected to the new panel. the elevator supports primary recall only and shall remain so.

  15. Mar 2014
    Issued Permit 201403241504 $$$ $14,600

    To erect electric, projecting, double faced sign. ** compliance with maher ordinance no.155-13 not required **.

  16. Mar 2014
    Issued Permit 201403241506 $$$ $6,000

    To erect electric, projecting, single faced sign. ** compliance with maher ordinance no.155-13 not required **.

  17. Mar 2014
    Issued Permit 201403241491 $$$ $4,410

    Awning- compliance with maher ordinance no.155-13 not required.

  18. Apr 2014
    Permit 201404042508 $$$ $6,820

    Install a fire system in a new kitchen hood supplied by others. t.i. app#201308265189. n/a for the maher ordinance #155-13.

  19. Apr 2014
    Permit 201404113031 $$$ $5,000

    Revision to 201401247033 new ada rooms proposed and notification devices shall be added in accordance with 2013 nfpa 7s section 18.4.5 throu 18.4.5.3. devices shown as a 2nd phase on prev approved set of plans where due to a partial remodel of the basement and gr fl the existing conventional fire al.

  20. Nov 2015
    Permit 201511253588 $$$ $78,500

    Reroofing; n/a maher ord. 155-13.

  21. Jan 2016
    Issued Permit 201601116782 $$$ $4,000

    Existingelevator is being upgraded & addtl functions shall be connected to the existingfire alarm system.primary recall is already part of the system functions, but secondary recall, fire hat illumination, shunt trip & back up battery shunt shall be added to the required safety function list.a smoke detector.

DBI holds 55 permits for this parcel, most of them tenant improvements on individual floors. The timeline shows the 24 largest by stated cost, plus the earliest on file; the DBI query in the sources below returns all 55. 9 of them are nominal $1 street-space or sidewalk permits. 5 expired or cancelled permits are not shown.