2323 Sacramento Street
Pacific Heights · San Francisco, CA 94115
-
1973
Operation Concern began here at Pacific Medical Center in 1973 as a counselling programme, growing into mental health programmes and a clinical intern training scheme.
-
Jan 1984
Additions alterations or repairs.
-
Aug 2003
Sign permit-non-electric, wall, single faced.erect flat alumimun panel, address sign.
-
Jun 2013
Add 22 gallon propane tank as secondary fuel source for existing generator.(natural gas fired) provide rack to secure propane tank.
-
Sep 2017
Existing roof access door to be tied into fire alarm with new hardware, upon activation of alarm, door will unlock per sffc sec 504.31.
-
Aug 2020
Install (1) 3'9" x 2' 10" x 2" panel sign (sutter health, sutter pacific medical foundation) non electric wall sign.
-
Jan 2024
Change of use and occupancy: prov. a senior res. care facility. basement: 1 ada parking and renovate existing kitchen, laundry room and admin areas.1/f: provide 12 sleeping units, medical office, dining room, reception. 2/f: provide 17 sleeping units, activity/nursing room. total capacity 29 units/39 bed.
-
Mar 2024
Ab-017 interior demolition only. nonstructural walls, doors, and frames. electrical and plumbing fixtures.
-
Apr 2024
The existing t-bar ceiling is removed and there 152 existing sprinklers that need to be raised/modified after demolition is complete.
-
Jul 2024
Strengthen level 1 podium slab with fiber reinforced polymer(frp).approximately 150sf.strengthen interior sheerwall with frp on both sides, approximately 350 sq ft.
-
Dec 2024
Remodel of existing fire sprinkler system 225 pendent sprinklers.
-
Jul 2025
Revision to 202401083567. voluntary strengthening to existing concrete columns in basement via steel jacketing, 10 columns in total.
-
Sep 2025
Ul300 fire suppression system installation.
-
Oct 2025
Revision to 202401083567: swapping out e) concrete column for a steel column for feasibility of construction.
-
Nov 2025
Revision to permit 202401083567. remove existing cement plaster and install new gypsum sheathing and cement plaster. install new wood siding.
-
Jan 2026
Provide new fire alarm system with horn strobes to meet cbc r-2.1 requirements for full smoke detection and delayed egress. building permit 202401083567.
-
Aug 2026
As built permit application 202502120163. per inspector request: 1) change ansul module description 2) add horn strobe on roof 3) add inspector test valve to drawing. building permit 202401083567.
-
Aug 2026
Fire only as built revision 202502120163 and ref buildling permit 202401083567 and 202608136523- add to device descrpition and add co to matrix as supervisory.